Remove bolts - B - (tightening torque 10 Nm).

-

Slide bracket - C - out of mount of condenser -  E - downward - arrows -.

-

Remove the reservoir - D - from the condenser -  E - - arrow -.

-

Seal open connections (against dirt and moisture penetration).

Installing

‹› There are different versions of the condenser and bracket -  C - depending on the production time period. As a running change in MY 2006, the

mounting was changed from a metal bracket attached by screws to a plastic bracket held in place by expansion clips.

‹› Fluid reservoir - C - and condenser - B - is available in different versions. At start of production, reservoirs were installed. which had o-rings - A -

and - B - on the reservoir connections.