audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Air Intake Housing|Page 14099 > < Air Intake Housing|Page 14097
Page 8
background image

‹› When installing A/C unit, make sure the two coolant pipes of the heater core do not get caught and bent or damaged on plenum chamber or noise

insulation mat.

‹› Observe wiring harness, individual electrical wiring connections may get damaged when pulling on harness.

-

Connect condensation water drain to connection on A/C unit and check condensation water drain for correct seating. Refer to => [ Condensate
Drain Hose ] See: Evaporator Drain Tube/Service and Repair. 

-

Reinstall removed components in reverse order of removal except driver storage compartment.

‹› When installing the instrument panel, make sure that the "defrost " intermediate piece its properly on A/C unit and the defrost vent does not pinch

the intermediate piece.

‹› After installing the instrument panel, check the output direction and distribution of the air flow from the defroster vent to the windshield.

-

Connect coolant hoses properly to heater core. Observe markings: 

A Supply hose from cylinder head
B Return to the coolant pump

-

Connect refrigerant lines to expansion valve. Refer to => [ Refrigerant Lines, Disconnecting from Expansion Valve ] See: Service and
Repair/Removal and Replacement/Refrigerant Circuit. 

-

Check installation position of coolant hoses to heater cores (they must not contact components which grow hot) and position and state of heat
protection insulation applied to coolant hoses if necessary (not installed on all engine types).

-

Bleed coolant circuit.

-

Check coolant circuit for leaks, pay particular attention to the connection between coolant hoses and heater core. Refer to=> [ Heat Exchanger ] 
See: Heater Core/Service and Repair/Heat Exchanger 