A3 L4-2.0L Turbo (BPY) (2006)
Tip:
Please do not carry out any other work on the vehicle during "Update - Programming" (Process could be interrupted).
Tip:
If, during the "Update - Programming", a fault message is displayed:
-
Confirm that VAS 5051 or VAS 5052 diagnostic tool power supply is adequate and that ALL appliances with high electromagnetic radiation (i.e.
mobile phones) are switched OFF.
-
The "Update - Programming" process must then be started from the beginning using the "Repeat" button (arrow). DO NOT use the "Cancel"
button.
Once "Update - Programming" is complete, the control module must be re-initialized.
-
The tester requests you to switch the ignition OFF
-
Switch ignition OFF.
-
Wait 20 seconds and switch ignition ON.
Similar screen appears.
-
Print out the displayed screen.
-
Attach a copy of print to vehicle Repair Order.
-
Select forward arrow on navigation bar.
Fault memories, erasing after "Update - Programming". To erase ALL fault memories: