audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Turbocharger Vacuum Diaphragm, Checking|Page 4088 > < Turbocharger Vacuum Diaphragm, Checking|Page 4086
Page 2
background image

-

Connect the hand vacuum pump VAS 6213 and the pressure regulator valve VAS 6342 to the vacuum diaphragm and to connection II on the 
turbocharger tester V.A.G 1397A, as illustrated.

-

Close pressure control valve VAS 6342 on lever - 1 -.

-

Adjust slide ring - 1 - on hand vacuum pump VAS 6213 to - B - position for "Pressure".

-

Switch on turbocharger tester V.A.G 1397A and adjust slide switch to position II.

-

Secure dial gauge holder VW 387 on turbocharger - arrow -.

NOTE:  The mm specifications apply to the value read out (includes 1 mm preload).

-

Secure dial gauge 0-30 mm VAS 6341/1 with dial gauge extension, 30 mm VAS 6341/3 and flat pickup VAS 6341/4 to dial gauge holder VW
387.

Turbocharger Vacuum Diaphragm, Checking|Page 4088 > < Turbocharger Vacuum Diaphragm, Checking|Page 4086