The adaption function makes it possible to implement and store the following modification:

  • ◆ Setting of ultrasonic sensors can be adjusted such that they react less sensitively.

Performing adaption (function 10)

 
→ Indicated on display:
Rapid data transfer     HELP
Select function XX
  • ‒ Press keys -1- and -0-.
 
→ Indicated on display:
Rapid data transfer     Q
10 - Adaption
  • ‒ Confirm input with Q key.
 
→ Indicated on display:
Adaption
Feed in channel No.
  • ‒ Press keys -0- and -1-.
 
→ Indicated on display:
Adaption    Q
Channel display 10
  • ‒ Confirm input with Q key.
 
→ Indicated on display:
The sensitivity level of the sensors is displayed: e.g. 100 %
Channel 1    Adaption    100    ⇒
Sensitivity in %         (-1    3-L    

Note:

The maximum ultrasonic sensor setting made at the factory is 100 % and can be reduced to 50 %.

  • ‒ Press ⇒key.
 
→ Indicated on display:
Channel    1    Adaption    100        
Enter adaption value XXXXX
  • ‒ Enter sensitivity value,
    e.g. 75 % = 00075
 
→ Indicated on display:
Channel 1 Adaption 100    Q
Enter adaption value    00075
  • ‒ Confirm input with Q key.
 
→ Indicated on display:
Channel 1 Adaption 75    Q
Sensitivity in %     (-1    3-L
  • ‒ Confirm input with Q key.
 
→ Indicated on display:
Channel 1 Adaption 75    Q
Store changed value?
  • ‒ Confirm input with Q key.
 
→ Indicated on display:
Channel 1    Adaption    75    ⇒
Changed value is stored
  • ‒ Terminate adaption of sensitivity with the ⇒key.
 
→ Indicated on display:
Rapid data transfer     HELP
Enter address word XX