Ultrasonic interior monitor self-diagnosis
Fault table for interior monitor:
Notes:
-
◆ The following table lists all the faults, with the corresponding 5-digit code numbers, that can be recognised by the ultrasonic sensors and printed out by the V.A.G 1551.
-
◆ Fault codes appear only on print-out.
-
◆ Before replacing a component shown as faulty, check wiring and connections to component as well as earth connections according to current flow diagram.
-
◆ After carrying out repairs activate and deactivate system once. Then interrogate fault memory again with fault reader V.A.G 1551 and erase memory.
-
◆ All static and sporadic faults are stored in the fault memory:
When a fault occurs it is immediately identified as a static fault. If fault does not occur again it is registered as a sporadic fault. "/SP" appears on the right of the display.
-
◆ All faults present are set to sporadic after activation and are only stored as being static if they are still present on completion of checking.
-
◆ Sporadic faults which no longer occur after 50 activation cycles are erased automatically.
-
◆ The 3-digit fault type number appearing next to the fault code is a data code which can be ignored.
V.A.G 1551 print-out
|
Possible causes of fault
|
Fault remedy
|
01379
|
|
|
Switch for interior monitor -E183
|
- Wiring defect between switch for interior monitor -E183 and the ultrasonic sensors control unit -J347 - Switch for interior monitor -E183 defective
|
- Check and, if necessary, repair wiring and connections according to the current flow diagram. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
Short to earth 1)
|
|
- Replace switch for interior monitor -E183
|
01380
|
|
|
Alarm triggered by sensor for ATW rear left
|
- Alarm triggered by attempted forced entry at rear left window or following a functional test - False alarm.
|
- Erasing fault memory Performing functional test =>Page 01-127.
|
01381
|
|
|
Alarm triggered by sensor for ATW rear right
|
- Alarm triggered by attempted forced entry at rear right window or following a functional test - False alarm.
|
- Erasing fault memory Performing functional test =>Page 01-127.
|
1) Fault is set if earth is applied for more than 1 minute.
V.A.G 1551 print-out
|
Possible causes of fault
|
Fault remedy
|
01382
|
|
|
Alarm triggered by sensor for ATW front left
|
- Alarm triggered by attempted forced entry at front left window or following a functional test - False alarm.
|
- Erasing fault memory Performing functional test =>Page 01-127.
|
01383
|
|
|
Alarm triggered by sensor for ATW front right
|
- Alarm triggered by attempted forced entry at front right window or following a functional test - False alarm.
|
- Erasing fault memory Performing functional test =>Page 01-127.
|
65535
|
|
|
Control unit defective
|
- Control unit for ultrasonic sensors -J347 defective
|
- Replace control unit for ultrasonic sensors -J347
|
|