audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Additional safety precautions for side airbag > < Airbag safety precautions
General Body Assembly, Interior (Repair groups 68, 69, 70, 72, 74)
Airbag safety precautions
Safety precautions when working on airbag
  • ◆ Testing, removing, installing and repair work may only be performed by qualified personnel.
  • ◆ Do not test with a test lamp, voltmeter or ohmmeter.
  • ◆ The airbag system may only be checked with fault reader V.A.G 1551/1552 and when installed. An exception is the self-cancelling ring with slip ring.
  • ◆ Always disconnect power supply when working on the airbag system.
    Detach battery earthing strap/cable, cover over negative terminal.
    No waiting period is required after disconnecting the battery.
  • ◆ There must be no-one in the vehicle when the battery is being connected.
  • ◆ Airbag components must neither be opened nor repaired. Always use new components.
  • ◆ The interval for replacing the airbag units no longer applies.
  • ◆ Always observe the following sequence when replacing an airbag unit:
  •     1 -    Remove old airbag unit and place down with padding facing upwards; with head airbag observe procedure for head airbag
  •     2 -    Take new airbag unit from transport container and store with padding facing upwards; with head airbag observe procedure for head airbag => Page 69-56
  •     3 -    Immediately place old airbag unit into transport container.
  •     4 -    Install new airbag unit into vehicle.
  • ◆ The airbag units should be installed immediately after removing them from their transport containers.
  • ◆ If work is interrupted, the airbag unit should be replaced in its transport container.
  • ◆ The airbag units must not be left unattended.
  • ◆ Airbag units which have been removed must stored with the padding facing upwards with exception of head airbag => Page 69-56
  • ◆ Airbag units which are dropped on a hard surface or are damaged must not be used.
  • ◆ The airbag unit must not be treated with grease, cleaning agents or similar, and must not, even for a short time, be exposed to temperatures above 100 °C.
  • ◆ Airbag units which were not triggered must be marked and be sent back to manufacturer for disposal (use transport containers for airbag units).

Additional safety precautions for side airbag > < Airbag safety precautions