audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

O-ring seals for refrigerant circuit > < Air conditioner pressure switch -F129
Heating, Air Conditioner
Repairing refrigerant circuit
Remove and install High-pressure sensor -G65
 
A87-0262
  • ‒ → Detach connector.
  • ‒ Remove High-pressure sensor -B-
    Tightening torque: 5 Nm
  • ‒ Replace O-ring seal -A- (10.8 mm; 1.8 mm) =>Page 87-22.

Notes:

  • ◆ The refrigeration capacity cannot be checked if sender -G65 is removed - control unit -J293 does not switch on the compressor.
  • ◆ The refrigerant circuit remains closed - connection with valve.
  • ◆ Check function of high-pressure sensor -G65 and signal emitted =>Page 01-225.

O-ring seals for refrigerant circuit > < Air conditioner pressure switch -F129