O-ring seals for refrigerant circuit >
< Air conditioner pressure switch -F129
A3 Mk1
Heating, ventilation, air conditioning system
Heating, air conditioner
Air conditioner
Repairing refrigerant circuit
Remove and install High-pressure sensor -G65
Heating, Air Conditioner
Repairing refrigerant circuit
Remove and install High-pressure sensor -G65
‒
→ Detach connector.
‒
Remove High-pressure sensor -B-
Tightening torque: 5 Nm
‒
Replace O-ring seal -A- (10.8 mm; 1.8 mm) =>Page
87-22
.
Notes:
◆
The refrigeration capacity cannot be checked if sender -G65 is removed - control unit -J293 does not switch on the compressor.
◆
The refrigerant circuit remains closed - connection with valve.
◆
Check function of high-pressure sensor -G65 and signal emitted =>Page
01-225
.