| Push operating rod with manual selector valve into valve body as far as the stop in direction of -arrows- and tighten bolt securing lever. |
l
| Tightening torque: 4 Nm |
Note t
| Before adjustment can be performed, the manual selector valve must be inserted in the valve body as far as it will go. Counter-hold in direction of -arrow- when tightening bolt. |
t
| Do not apply pressure to small limiting lever for steel spring, otherwise adjustment will be incorrect. |
t
| Check: in selector lever position “1”, manual selector valve must be flush with outside of valve body. |
|
|
|