audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Diagram of connections for charge pressure control system and vacuum system > < Safety precautions
Test requirements for checking turbocharging system
Test requirements for checking turbocharging system
l  Coolant temperature at least 80 °C.
l  Fault memory of engine control unit interrogated.
l  No leaks in the intake and exhaust systems. Effects of leaks → Chapter.
l  No leaks in vacuum hoses.
l  Vacuum pipe to charge pressure regulating valve not obstructed, loose or leaking.
l  No faults on engine or injection system (e.g. compression pressure or injectors).
   

Diagram of connections for charge pressure control system and vacuum system > < Safety precautions