→ Display on VAS 5051:
-
‒ Check readiness code in display zone -1-.
-
‒ Specified value: 0 0 0 0 0 0 0 0
|
---|
|
Display zones
|
|
1
|
2
|
3
|
4
|
Display group 086: Readiness code
|
Display
|
0 0 0 0 0 0 0 0
|
X X X X X X X X
|
X X X X X X X X
|
|
Display
|
Ready bits Completed tests
|
Individual tests performed
|
Individual tests performed
|
|
Range
|
1 = not completed 0 = completed
|
1 = not completed 0 = completed
|
1 = not completed 0 = completed
|
|
Specified value
|
0 0 0 0 0 0 0 0
|
X X X X X X X X
|
X X X X X X X X
|
|
Note:
|
Explanation of readiness code => Page 01-68
|
|
Note on display zone 1:
Display zone 1 is the most important. This display indicates which system has been checked by the self-diagnosis since the last time the fault memory was erased or since installation of a new control unit. After erasing the fault memory, all testable values are set to "1" and then to "0" after successful completion of the test.
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
Notes on display group 086, display zone 1
|
|
|
|
|
|
|
|
|
Catalytic converter diagnosis - Display 0 = Test was carried out - Display 1 = Test was not carried out (produce readiness code - .
|
|
|
|
|
|
|
|
|
Display always 0
|
|
|
|
|
|
|
|
|
Activated charcoal filter system - Display 0 = Test was carried out - Display 1 = Test was not carried out (produce readiness code - .
|
|
|
|
|
|
|
|
|
Display always 0
|
|
|
|
|
|
|
|
|
Display always 0
|
|
|
|
|
|
|
|
|
Lambda probes - Display 0 = Test was carried out - Display 1 = Test was not carried out (produce readiness code - .
|
|
|
|
|
|
|
|
|
Lambda probe heater - Display 0 = Test was carried out - Display 1 = Test was not carried out (produce readiness code - .
|
|
|
|
|
|
|
|
|
Display always 0
|
Note:
The readiness code is only produced when all display digits in display zone 1 are set to "0".
If the specification "0 0 0 0 0 0 0 0" is achieved in display zone 1:
-
‒ Press the ◂ key.
-
‒ Interrogate fault memory to check (there must not be any stored faults).
If specified value is not attained:
-
‒ Produce the readiness code => Page 01-70.
|