audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Producing the readiness code > < Readiness code
Motronic injection and ignition system (4-cyl. turbo)
Readiness code
Reading out readiness code

Test sequence

 
A01-0122
  • ‒ Connect vehicle diagnostic, testing and information system VAS 5051 and select vehicle system "01 -Engine electronics" in the selection. For this purpose, the engine must be running at idling speed.

→ Display on VAS 5051:

  • ‒ Under -1- select the diagnostic function "08 - Read measured value block".

 
A01-0130

→ Display on VAS 5051:

  •     1 -    Enter display group
    max. input value = 255
  • ‒ Enter "086" for "display group number 086" in zone -2- and confirm the entry by pressing the Q key.
 
A01-0139

→ Display on VAS 5051:

  • ‒ Check readiness code in display zone -1-.
    • ‒ Specified value: 0 0 0 0 0 0 0 0

Display zones

1

2

3

4

Display group 086: Readiness code

Display

0 0 0 0 0 0 0 0

X X X X X X X X

X X X X X X X X

Display

Ready bits
Completed tests

Individual tests performed

Individual tests performed

Range

1 = not completed
0 = completed

1 = not completed
0 = completed

1 = not completed
0 = completed

Specified value

0 0 0 0 0 0 0 0

X X X X X X X X

X X X X X X X X

Note:

Explanation of readiness code => Page 01-68

Note on display zone 1:

Display zone 1 is the most important. This display indicates which system has been checked by the self-diagnosis since the last time the fault memory was erased or since installation of a new control unit. After erasing the fault memory, all testable values are set to "1" and then to "0" after successful completion of the test.

X

X

X

X

X

X

X

X

Notes on display group 086, display zone 1

Catalytic converter diagnosis
- Display 0 = Test was carried out
- Display 1 = Test was not carried out (produce readiness code
- .

Display always 0

Activated charcoal filter system
- Display 0 = Test was carried out
- Display 1 = Test was not carried out (produce readiness code
- .

Display always 0

Display always 0

Lambda probes
- Display 0 = Test was carried out
- Display 1 = Test was not carried out (produce readiness code
- .

Lambda probe heater
- Display 0 = Test was carried out
- Display 1 = Test was not carried out (produce readiness code
- .

Display always 0

Note:

The readiness code is only produced when all display digits in display zone 1 are set to "0".

If the specification "0 0 0 0 0 0 0 0" is achieved in display zone 1:

  • ‒ Press the ◂ key.
  • ‒ Interrogate fault memory to check (there must not be any stored faults).

If specified value is not attained:

  • ‒ Produce the readiness code => Page 01-70.

Producing the readiness code > < Readiness code