Test sequence
Test sequence
–  Connect vehicle diagnostic, testing and information system -VAS 5051- or fault reader -V.A.G 1551- and select engine electronics control unit by entering “address word ” 01. For this purpose, the ignition must be switched on.
   
Indicated on display:
–  Enter “08” for the function “Read measured value block” and confirm entry with the Q key.
 
Rapid data transfer            HELP
Select function XX                    
Indicated on display:
–  Enter “004” for “Display group number 004” and confirm entry with the Q key.
–  Check specified value for intake air temperature sender in display zone 4:
 
Reading measured value block                  Q
Enter display group number XXX       
 Display zones
 1234
Display Group 004: Intake air temperature with engine idling
Displayxxxx rpmxx.x Voltxxx.x °Cxxx.x °C
ReadoutEngine speedBattery voltageCoolant temperatureIntake air temperature
Specificationxxxx rpm12.0...15.0 V80.0...110.0 °Cfrom ambient temperature to 80°C. If a temperature is displayed which deviates greatly from the ambient temperature of the sender, check sender and sender wiring for contact resistances and open circuit.
Note:   If 9 °C or 30 °C are indicated continuously, check the wiring connections → Chapter
If approx. ambient temperature is indicated and a fault is stored in the fault memory with regard to -G42-, check the sender → Chapter

   