Switch on ignition.
–
Connect multimeter between sockets 1 and 3 of test box to measure voltage.
t
Specification: approx. battery voltage
If specification is not attained:
–
Check wiring and earth connection to power supply relay -J363-:
→ Current flow diagrams, Electrical fault finding and Fitting locations
If no wiring fault is detected:
–
Replace the power supply relay.