audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Interrogating fault memory > < General information
Electrical system Self-diagnosis
Automatic headlight range control self-diagnosis
Starting automatic headlight range control self-diagnosis

Requirements:

  • ● Vehicle diagnostic, testing and information system VAS 5051 connected up and vehicle self-diagnosis selected
  • ● Ignition on
Attention:
Heed safety precautions => Page 01-1.
 
A01-0120

Sequence of operations

→ Display on VAS 5051:

  • ‒ From list -1- select vehicle system "55 - Headlight range control".
  • ‒ Wait until next display appears.
 
A01-0191

→ Display on VAS 5051:

  •     1 -    Headlight range control unit identification
  •     2 -    List of diagnosis functions => Page 01-486

Headlight range control unit identification (example)

55 - Headlight range control

Vehicle system

4B0907357

Part No.; Assignment
=> Parts List

HEADLIGHT RANGE CONTROLLER 1) D004 2)

1)
2)

Component designation
Data level (software version)

Code 13

Control unit encoding (checking => Page 01-505)

Dealership number 12345

Workshop code of VAS 5051 with which encoding was last performed

Diagnosis functions

Page

02

Interrogating fault memory

01-487

03

Final control diagnosis

01-495

04

Basic setting

01-498

05

Erasing fault memory

01-502

06

End of output

01-504

07

Encoding control unit

01-505

08

Reading measured value block

01-508

09

Reading individual measured value

-

10

Adaption

-

11

Login procedure

-

Interrogating fault memory > < General information