Adaption > < Function status register
Description of operation
Description of operation
Production diagnosis is a special mode for checking the wiring and correct functioning of the navigation system. It involves automatic checking of the individual fault locations, filing of the result in the so-called function status register (measured value block 007) and permanent storage.
Production diagnosis can be disabled/enabled by way of "Adaption" (channel 03) → Chapter.
Production diagnosis is also disabled when a navigation CD is inserted.
The “Erasing fault memory” function also resets the function status register.
Test requirements:
t  No navigation CD inserted
t  Navigation system switched on
t  Tyre circumference adapted → Chapter
t  Adaption of number of pulses per wheel revolution (GALA) performed → Chapter
t  Erase fault memory → Chapter
t  Drive vehicle at a speed of at least 10 km/h
t  With vehicle stationary, engage reverse gear for at least 2 seconds
Value “255” will be displayed in measured value block 007 if production diagnosis has been implemented correctly (all test requirements met) and navigation system is OK.
   