audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Removing and installing right footwell vent temperature senderG262 > < Removing and installing evaporator output temperature senderG263
Removing and installing left footwell vent temperature senderG261
Removing and installing left footwell vent temperature sender -G261-
  Note
t  The left footwell vent temperature sender -G261- was only fitted on vehicles with manually controlled air conditioner at the start of production (being gradually discontinued).
t  On vehicles with manually controlled air conditioner, the measured value of this sender is not evaluated by the air conditioning system control unit -J301-. A fault at the left footwell vent temperature sender -G261- is not detected (not required for control purposes).
Removing and installing
–  Remove the driver's storage compartment. → General body repairs, interior; Rep. gr.68
   
–  Remove the left footwell vent -A- (driver side). → General body repairs, interior; Rep. gr.68
–  Reach through the opening between the air conditioning unit on the left and the central tube (dash panel cross-member) or the support at the air conditioning unit on the left and turn the sender -B- to a position in which the connector -A- can be unplugged.
  A87-0684
–  Unplug the connector -A- (e.g. using pointed nose pliers).
–  Turn the sender -B- through 90° and pull it out of the air conditioning unit.
–  On installation, pay attention to correct positioning of the seal -C-.
  Note
t  If it is not possible to turn the sender -B- or if the sender -B- is inaccessible on account of other components, remove the dash panel → General body repairs, interior; Rep. gr.70.
t  This illustration shows the sender -B- with the dash panel removed. With the dash panel in position, the sender -B- can be seen from underneath with the footwell vent removed (the part of the sender with the temperature sensor can be seen in the air duct).
  A87-0700

Removing and installing right footwell vent temperature senderG262 > < Removing and installing evaporator output temperature senderG263