| Detach vacuum hose at vacuum unit for exhaust gas recirculation -1-. |
–
| Connect hand-operated vacuum pump -V.A.G 1390- or -VAS 6213- to valve. |
–
| Use hand-operated vacuum pump to generate vacuum. |
l
| The linkage of the exhaust gas recirculation change-over should move -arrow-. |
If the linkage does not move or only moves jerkily: |
t
| The vacuum unit is defective |
t
| If the change-over flap for exhaust gas recirculation is sticking |
|
|
|