| Unscrew bolts -arrows- from air cleaner (top section). |
Note –
| Lift up air cleaner (top section) and take out air filter element. |
Note t
| Always use genuine part for air filter element. |
t
| Hose connections and hoses for charge air system must be free of oil and grease before assembly. Do not use any lubricants containing silicone when assembling. |
t
| The air cleaner housing must be clean. |
t
| Secure all hose connections with the correct type of hose clips (same as original equipment) → Parts catalogue |
t
| To prevent malfunctions, cover all critical parts of the engine air intake tract (air mass meter, intake pipes, etc.) with a clean cloth when blowing out the air cleaner housing with compressed air. |
t
| Please observe requirements for disposal. |
–
| Check for salt residue, dirt and leaves in air mass meter and air intake hose (engine intake side). |
–
| Check for dirt in air intake hose from air duct. |
|
|
|