| Connect hand vacuum pump -VAS 6213- to activated charcoal filter solenoid valve 1 -N80-. |
–
| Connect contacts of activated charcoal filter solenoid valve 1 -N80--1- to battery using test leads. This will open activated charcoal filter solenoid valve 1 -N80-. |
Then immediately operate hand vacuum pump -VAS 6213- several times. |
l
| Vacuum should build up. |
–
| Again disconnect battery to cut off current supply. |
If vacuum does not build up: |
–
| Renew dual non-return valve -1-. |
Dual non-return valve, activated charcoal filter solenoid valve 1 -N80- and plastic hoses are combined as one unit and can only be renewed together. |
|
|
|