audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Removing and installing intake manifold flap motor V157 > < Removing and installing air mass meter G70
Intake manifold - exploded view
   
Intake manifold - exploded view
1 - 22 Nm
2 - Lower connecting pipe for exhaust gas recirculation
q   When installing, first tighten finger-tight and then tighten to specified torque
3 - Gasket
q   Renew
4 - Gasket
q   Renew
5 - Changeover flap for exhaust gas recirculation
6 - 10 Nm
7 - 10 Nm
8 - Gasket
q   Renew
9 - Upper connecting pipe for exhaust gas recirculation
q   When installing, first tighten finger-tight and then tighten to specified torque
10 - 22 Nm
11 - 10 Nm
12 - 22 Nm
13 - Bracket
14 - 5 Nm
15 - Intake manifold
q   Removing and installing → Chapter
16 - O-ring
q   Renew
17 - Gasket
q   Renew
18 - Mechanical exhaust gas recirculation valve
19 - O-ring
q   Renew
20 - Intake manifold connection
q   With intake manifold flap motor -V157-
21 - 10 Nm
22 - 10 Nm
23 - Gasket
q   Renew
24 - 22 Nm
25 - Exhaust gas recirculation cooler
26 - 10 Nm
27 - Gasket
q   Renew
28 - 22 Nm
q   Renew

   

Removing and installing intake manifold flap motor V157 > < Removing and installing air mass meter G70