audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Removing and installing control pipe for exhaust gas pressure sensor 1G450 > < Removing and installing exhaust gas pressure sensor 1G450
Removing and installing control pipe for pressure sensors
Removing and installing control pipe for pressure sensors
Removing
–  Remove engine cover panel → Chapter.
   
–  Remove pressure differential sender -G505--2- → Chapter.
  A26-10722
–  Detach heat insulation sleeve and remove exhaust gas pressure sensor 1 -G450--3- → Chapter.
–  Detach clamp -1-
  A26-10935
–  Remove noise insulation -1- → Rep. gr.66.
  A10-10917
–  Detach clamp -2-, unscrew bolts -1- and take out filter.
  A26-10925
–  Disconnect control pipe -2- from exhaust pipe behind particulate filter.
  A26-10937
–  Remove nuts -2-.
  Note
Disregard -item 1-.
  A26-10723
–  Remove bolt -4- and move particulate filter towards rear.
–  Slacken nut -2- only until control pipe is loose.
  A26-10935
–  Guide out and remove control pipe.
Installing
–  Install in reverse order.
l  Tightening torque: Lambda probe - exploded view → Chapter
  Note
t  Before installing, blow out control pipes to particulate filter towards particulate filter with compressed air (pipes can become obstructed or may ice up due to condensation).
t  Make sure that hoses are securely fitted and seal properly.
  A26-10936

Removing and installing control pipe for exhaust gas pressure sensor 1G450 > < Removing and installing exhaust gas pressure sensor 1G450