background image

‹› In MY 2005 as a running change, reservoirs, that had two seals on the connections, were installed. Each a seal - B - and an o-ring -  C -.

Installation is carried out in the reverse order, when doing this note the following:

Before installing fluid reservoir Refrigerant R134a - Servicing

-

Clean the contact surface on the condenser - C -

-

Replace O-ring seals - A - and - B - => [ Refrigerant Circuit O-Ring Seals ] See: Description and Operation/Refrigerant Circuit O-Ring Seals

-

Replace seals - B - and O-ring seals - C -.