A3 Quattro L4-2.0L Turbo (CBFA) (2009)
-
Insert the rain/light recognition sensor (G397 ) in the retaining plate and press it onto the windshield without forming bubbles.
‹› The rain/light recognition sensor (G397) must engage audibly in the retaining plate and have no embedded objects or bubbles between it and the
windshield to function properly.
-
Secure the rain/light recognition sensor (G397 ) to the retaining plate with the retaining spring.
-
Attach interior mirror offset at 30° from installation position.
-
Turn interior mirror clockwise until stop.
-
Code the new rain/light recognition sensor (G397 ).
-
Select the function or path:
-
Follow further instructions on display of (VAS 5051B).