A3 Quattro V6-3.2L (BUB) (2008)
-
Remove bolts from hydraulic unit bracket - 1 -. Tightening specification 8 Nm.
Unfastening control module from hydraulic unit
-
Set hydraulic unit on a clean and level surface with control module facing downward.
-
Remove internal Torx bolts - arrows - from hydraulic pump.
CAUTION!
The hydraulic pump must not be separated from the hydraulic unit.