Measures to be taken in the event of temperature increase downstream of evaporator
   
Measures to be taken in the event of temperature increase downstream of evaporator
–  Pinch off both coolant hoses between engine and heating system heat exchanger with hose clamps up to Ø 25 mm -3094-.
–  Repeat cooling output test → Chapter.
l  Do the two measured values in display zones “3” and “4” of display group “009” differ by less than 3 °C from the measured value of the evaporator outflow temperature sender -G263- (display zone “1” of display group “010”)?

yes

no
–  Detach hose clamps at both coolant hoses.
–  Check correct installation of sender with measured value deviation, as well as checking electrical connections for contact resistance.
–  Check actuation of left temperature flap control motor -V158- and right temperature flap control motor -V159- → Chapter (perform final control diagnosis).
–  Check position of temperature flaps and corresponding levers for left temperature flap control motor -V158- and right temperature flap control motor -V159- and → Chapter and → Chapter
–  Eliminate cause of incorrect measured value. Replace defective sender.

   