| Unplug connector -A- from fresh air blower control unit -J126-. |
–
| Measure voltage between contact -6- and contact -3- at connector -A-. |
t
| Specification: 8....12 V DC (depending on sunlight intensity) |
–
| Connect up test lamp (12 V, max. 5 W) between contacts -6- and -3- at connector -A-. |
–
| Test lamp glows or lights (depending on sunlight intensity). |
Note t
| If the test lamp glows or lights, the solar roof is functioning properly. If the fresh air blower -V2- does not run, check freedom of movement of fresh air blower -V2-. If no fault is found, replace fresh air blower control unit -J126- with fresh air blower -V2-. |
t
| The electrical energy supplied is only approx. 1.5 W on shining halogen lamps onto the solar roof (fresh air blower -V2- rotates but air flow is hardly perceptible). |
|
|
|