audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Test step "3” > < Test step "2”
Temperature-sensitive resistances of temperature sensors/senders
   
Temperature-sensitive resistances of temperature sensors/senders
Temperature
measured at fitting location of temperature sensor/sender in “°C”
Resistance
of fresh-air intake duct temperature sensor -G89-
(and also ambient temperature sensor -G17-) in “kΩ”
Resistance
of right vent temperature sender -G151-, front vent temperature sender -G152-, left footwell vent temperature sender -G261-, right footwell vent temperature sender -G262- in “kΩ”
Resistance
of evaporator outflow temperature sender -G263- in “kΩ”
- 3018,10(141,00)(52,20)
- 209,95(85,00)(27,75)
-105,59(47,00)(15,50)
03,2829,009,00
52,5423,206,96
101,9918,605,44
151,5715,004,28
201,2512,203,40
251,0010,002,72
300,808,202,19
350,656,801,78
400,535,701,46
500,364,001,00
600,252,900,69

   

Test step "3” > < Test step "2”