Pin assignment of test box -V.A.G 1598A- with adapter cable -V.A.G 1598/11- |
Note t
| The contact assignment of the connectors “A” and “B” for the adapter cable -V.A.G 1598/11- is not identical to the assignment of the sockets at the test box -V.A.G 1598A-. |
t
| The contact assignment of the connector “C” for the adapter cable -V.A.G 1598/11- is identical to the assignment of the sockets at the test box -V.A.G 1598A-. |
t
| The contact assignment of the connector “D” for the adapter cable -V.A.G 1598/12- is identical to the assignment of the sockets at the test box -V.A.G 1598A-. |
t
| As the connectors to the operating and display unit, Climatronic control unit -J255- are distributed over two adapter cables (adapter cable -V.A.G 1598/11- and adapter cable -V.A.G 1598/12-), there is no earth connection for test purposes with the adapter cable -V.A.G 1598/11- connected. When performing electrical checks, it is therefore necessary for various test steps to take measurements with respect to a suitable earth point on the vehicle body or to use a second test box -V.A.G 1598A- (with the adapter cable -V.A.G 1598/12- connected, earth is applied to socket “13”). |
|
|
|