| Possible causes if display zone -1- indicates “Function unknown or cannot be implemented at present”: |
t
| Auxiliary heater had been switched on and is currently in “Run-on” mode. |
t
| Auxiliary heater control unit -J364- has received a message preventing actuation (e.g. insufficient fuel in tank) → Chapter (reading measured value block, display group 005). |
t
| Fault preventing actuation has been stored in auxiliary heater control unit -J364-. |
t
| To switch off heater, touch ← key and enter basic setting (display group number “033”) → Chapter. |
t
| If a fault occurs during the “Basic setting, heating on” function, the heater can only be started up again after switching it off by way of the “Basic setting, heating off” function. |
t
| If auxiliary heater operation is to be observed, touch key -3- to switch to “Reading measured value block” function. Touch key -4- to return to “Basic setting” function. |
|
|
|