| Unscrew cylinder head cover bolts (right-side) in the sequence -12 ... 1-. |
Caution Do not disconnect crankcase breather hose on USA models -arrow-. |
|
–
| Detach cylinder head cover and move clear to one side (crankcase breather hose remains connected). |
Installation is carried out in the reverse order; note the following: |
Note t
| Renew cylinder head cover gaskets if damaged. |
t
| Renew cylinder head cover bolts if gasket is damaged. |
–
| Clean sealing surfaces; they must be free of oil and grease. |
–
| Tighten bolts for cylinder head cover to final setting in the sequence -1 ... 12-. |
|
|
|