Measuring radial clearance |
Special tools and workshop equipment required |
Note t
| Do not interchange used bearings. |
t
| Bearing shells worn down to nickel layer must be renewed. |
–
| Remove main bearing caps and clean bearing caps and journals. |
–
| Place a length of Plastigage corresponding to the width of the bearing on the bearing journal or bearing shell. |
l
| The Plastigage must be positioned in the centre of the bearing shell |
–
| Mount main bearing cap and tighten to 30 Nm. Do not rotate crankshaft. |
–
| Remove main bearing cap once more. |
–
| Compare width of Plastigage with measurement scale: |
l
| New: 0.018 ... 0.045 mm. |
|
|
|