Components for the control and regulation of air conditioners up to Model Year 1996
Removing and installing operating and display unit -E87
Assignment of the operating and display unit -E87 -E87 up to Model Year 1996
|
---|
Part number
|
Special features
|
8D0 820 043 C
|
Static self-diagnosis, control is deactivated during self-diagnosis
|
8D0 820 043 D...G
|
- During the self-diagnosis, control is only switched off for final control diagnosis and basic setting - In vehicles with 6-cylinder engines, may only be combined with Zexel compressors
|
8D0 820 043 from H
|
For all vehicles up to Model Year 1996
|
Notes:
-
◆ Before removing -E87, interrogate fault memory .
-
◆ Note the precise assignment when replacing an operating and display unit:
=> Parts List
-
◆ After renewing the -E87, always:
- Check/correct code .
-
◆ If a new installed operating and display unit -E87 flashes after the ignition is switched on (for approx. 2 minutes), encode the -E 87 .
-
◆ If display is always 22 °C (71°F) after switching on ignition, regardless of the last setting, use the current flow diagram to rectify the power supply to -E87 (terminal 30).
-
◆ The display on the -E87 may be switched from °C°F and vice versa by pressing the "temperature +" button with the "recirculated air" button pressed.
Removing
|