Vehicle diagnostic, testing and information system -VAS 5051- is connected; vehicle self-diagnosis and vehicle system “01 - Engine electronics” is selected. When doing this the ignition must be switched on.
–
Connect voltage tester -V.A.G 1527 B- to contacts -1- (plus) and -2- of the connector.
Display on -VAS 5051-:
–
Under selection menu -1- select the diagnostic function “03 - Final control diagnosis”.
–
Press the button → until the secondary air inlet valve -N112- is actuated.
l
LED should flash slowly.
–
Exit function “03 - Final control diagnosis” by pressing the ← key.
–
Press “06 - End output”.
–
Switch off ignition.
If the LED lamp does not flash or lights up continuously:
To prevent damage to the electronic components, select appropriate measuring range before connecting the measuring cables and observe the test requirements.
–
Check for open circuit and short to positive or earth in the following wiring:
Connector Contact
Test box -V.A.G 1598/31- Socket
-2-
71
–
Eliminate open circuit in wiring (refer to current flow diagram).