| Detach vacuum hose -1- at combination valve. |
–
| Connect the hand vacuum pump -V.A.G 1390- to vacuum connection of combination valve. |
–
| Remove heat insulation mat. |
–
| Disconnect hose -2- at pipe leading to combination valve for secondary air. |
–
| Blow gently into pipe (do not use compressed air). |
l
| The combination valve must be closed; blowing through must not be possible. |
–
| Operate the hand vacuum pump. |
l
| The combination valve should open; it should now be possible to blow through the hose. |
If the combination valve does not open: |
|
|
|