audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Removing and installing secondary air inlet valve -N112 > < Secondary air system
6-Cylinder engine (5-valve turbo), Mechanics
Secondary air system
Removing and installing parts of secondary air system
 
A26-0295

The components for the secondary air system are located below the air duct between intake manifold and plenum chamber.

  • 6 Nm
  • Secondary air inlet valve N112
  • 10Nm
  • Large flat washer
    • ◆ For all three bonded rubber mountings on the secondary air pump bracket
  • Combination valve, left
  • Gasket
 
A26-0295
  • 10 Nm
  • Secondary air pump with air cleaner fitted
  • 10 Nm
  • Gasket
  • Combination valve, right
  • Secondary air pump bracket
    • ◆ Fitted to rear of intake manifold
  • 10 Nm
  • Screw-type clip
  • Connecting pipe
    • ◆ Between secondary air pump and combination valves
 
A26-0353

→ Fig.1    Location of secondary air inlet valve

-N112

  • ◆ Secured to bracket below control units together with connector for exhaust gas temperature at rear right of intake manifold next to secondary air pump motor -item 3-.

 
A26-0353

→ Fig.2    Location of secondary air pump motor

-V101

  • ◆ At rear left of intake manifold -item 4-.

Removing and installing secondary air inlet valve -N112 > < Secondary air system