Note:
You will now be instructed to: "Confirm kickdown".
-
‒ Fully depress accelerator pedal beyond kickdown point and keep it pressed.
Note:
During adaption the kick-down point "Kick-down ADP is running" is displayed on V.A.G 1551. After successful adaption of the kick-down point the V.A.G 1551 shows "Kick-down ADP OK".
-
‒ Check specified value in display zone 4:
|
---|
|
Display zones
|
|
1
|
2
|
3
|
4
|
Display group 063: Adapting kickdown function
|
Display
|
xx %
|
xx %
|
Kickdown
|
---
|
Display
|
Sender 1 for accelerator pedal position
|
Learned kickdown value sender 1 for accelerator pedal position
|
Kickdown
|
Adaption status
|
Range
|
|
|
Kickdown
|
Starting ADP process running ADP OK ERROR
|
Specified value
|
79...94 %
|
79...94 %
|
Kickdown
|
ADP OK
|
Note:
|
|
|
|
If "ERROR" is displayed: Interrogate fault memory => Page 01-9.
|
Notes:
-
◆ "ADP" in display zone 4 stands for adaption.
-
◆ If "ERROR" can be displayed, if e.g. accelerator pedal is not pressed when instructed by tester, or if accelerator pedal was released while adaption was already running but process was not yet complete.
In both cases it is necessary to exit the "Basic setting" mode and restart the adaption process afresh .
If specified value "ADP OK" is attained:
|