Basic setting
Basic setting
With engine stopped and ignition switched on, the following operation can be carried out with the "Function 04" basic setting:
-
◆ Adaption of the throttle valve control unit to the engine control unit => Display group 060
()
-
◆ Vehicles with automatic gearbox: Adaption of kickdown function of accelerator position sender to engine control unit =>Display group 063 ()
With the engine running, the following operations can be performed with the basic setting function:
-
◆ Adaption process of the Lambda control
Test conditions for operations with engine running
-
● No faults stored in fault memory
-
● Coolant temperature at least 80 °C.
-
● Electrical consumers switched off (radiator fan must not run during the test)
-
● Air conditioning switched off.
-
● Vehicles with automatic gearbox: Selector lever in position P or N
Test sequence
-
‒ Connect vehicle diagnostic, testing and information system VAS 5051 or fault reader V.A.G 1551 and select engine electronics control unit with "Address word" 01
For this purpose, the ignition must be switched on.
or, after each required process:
|