Self-diagnosis
Technical data for self-diagnosis
Equipment
-
◆ Fault memory: Non-volatile memory and volatile memory1).
-
◆ Rapid data transfer
1) Will be erased after 50th engine start if fault has not occurred again.
Available functions
Function
|
Ignition switched on
|
Engine idling
|
01
|
Interrogate control unit version
|
x
|
x
|
02
|
Interrogate fault memory
|
-
|
x
|
03
|
Control unit diagnosis
|
x
|
-
|
04
|
Introduce basic setting
|
x
|
x
|
05
|
Erase fault memory
|
x
|
x
|
06
|
Terminate output
|
x
|
x
|
|
---|
Function
|
Ignition switched on
|
Engine idling
|
07
|
Encode control unit
|
x
|
x
|
08
|
Read block of measured values
|
x
|
x
|
09
|
Read individual measured value
|
x
|
x
|
|