audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Producing the readiness code > < Readiness code
Motronic Fuel Injection and Ignition System (6-cyl. Turbo)
Readiness code
Reading the readiness code

Test sequence

  • ‒ Connect the vehicle diagnostic, testing and information system VAS 5051 or fault reader V.A.G 1551 and select the engine electronics control unit with "address word" 01 .
    For this purpose, the ignition must be switched on.
 
→ Indicated on display:
Rapid data transfer    HELP
Select function XX
  • ‒ Enter "08" to select the function "Reading measured value block" and confirm entry with Q key.
 
→ When adjacent display appears:
Reading measured value block    Q
Enter display group number XXX
  • ‒ Enter "086" for "display group number 086" and confirm entry with Q key.
 
→ Indicated on display:
Read measured value block 86    ⇒
    1    2    3    4
  • ‒ Check readiness code in display zone 1
    • ‒ Specification: 0 0 0 0 0 0 0 0

Display zones

1

2

3

4

Display group 086:Readiness code

Display

0 0 0 0 0 0 0 0

X X X X X X X X

X X X X X X X X

X X X X X X X X

Display

Ready bits
Completed tests

Individual tests performed

Individual tests performed

Individual tests performed

Range

1 = not completed
0 = completed

1 = not completed
0 = completed

1 = not completed
0 = completed

1 = not completed
0 = completed

Specification

0 0 0 0 0 0 0 0

X X X X X X X X

X X X X X X X X

X X X X X X X X

Note:

Explanation of readiness code => Page 01-99

Note on display zone 1:

Display zone 1 is the most important. This display indicates which system has been checked by the self-diagnosis since the last time the fault memory was erased or since installation of a new control unit. After erasing the fault memory, all testable values are set to "1" and then to "0" after successful completion of the test.

X

X

X

X

X

X

X

X

Notes on display group 086, display zone 1

Catalytic converter diagnosis
- Display 0 =test successfully completed
- Display 1 =test not (or not successfully) completed
- (Producing readiness code => Page 01-101)

Display always 0

Activated charcoal filter system
- Display 0 =test successfully completed
- Display 1 =test not (or not successfully) completed
- (Producing readiness code => Page 01-101)

Secondary air system
(display always 0, as no secondary air system available for this engine).

Display always 0

Lambda probes
- Display 0 =test successfully completed
- Display 1 =test not (or not successfully) completed
- (Producing readiness code => Page 01-101)

Lambda probe heater
- Display 0 =test successfully completed
- Display 1 =test not (or not successfully) completed
- (Producing readiness code => Page 01-101)

Display always 0

Note:

The readiness code is only produced when all display digits in display zone 1 are set to "0".

If the specification "0 0 0 0 0 0 0 0" is achieved in display zone 1:

  • ‒ Press ⇒key.
 
→ Display (function selection):
Rapid data transfer     HELP
Select function XX
  • ‒ Interrogate fault memory to check (there must not be any stored faults).

If specification is not attained:

  • ‒ Produce the readiness code => Page 01-101.

Producing the readiness code > < Readiness code