‒ Switch off air conditioner.
-
‒ Specification for display zone 4: "Compr.OFF"
-
‒ Switch on air conditioner by pressing "AUTO" key and select maximum warm or cold air setting. The compressor should run.
-
‒ Specification for display zone 4: "Compr. ON"
-
‒ Floor and release the accelerator quickly (short blip).
-
‒ Specification for display zone 4: The display should change from "Compr.ON" to "Compr.OFF" for a few seconds (air conditioner compressor shut-off during acceleration).
If the readout in display zone 4 is not as described:
-
‒ Connect test box V.A.G 1598/31 to wiring harness for engine control unit. Do not connect to the engine control unit itself.
=> Page 24-20.
-
‒ Test for open circuit and short to positive or earth in the following wiring connection:
|
---|
Test box V.A.G 1598/31 Socket
|
AC operating and display unit -E87 Contact
|
41
|
=> Current flow diagrams, => Electrical fault-finding => and Fitting locations binder
|
-
‒ Rectify short circuit or open circuit if necessary.
-
‒ If there are no faults in the wiring, test operation of air conditioner.
=> Heating, air conditioner; Repair Group 01; Self-diagnosis for air conditioner
|