audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Display group overview > < Encoding table
MPFI Fuel Injection and Ignition System
Reading measured value block
Reading measured value block

Note:

For engines with one Lambda probe only for bank 1 (emission standard ECE 15.04 => Encoding control unit, Page 01-52) a duplicate of the bank 1 values is always output in the measured value blocks for bank 2.

Test requirements:

  • ● Coolant temperature at least 85 oC.
  • ● Electrical consumers switched off (radiator fan must not run during the test)
  • ● Air conditioning switched off.
  • ● Vehicles with automatic gearbox: Selector lever in position P or N
  • ● No faults stored in fault memory

Work sequence

  • ‒ Connect up vehicle diagnosis, measurement and information system VAS 5051 or fault reader V.A.G 1551 and select engine electronics control unit with "Address word" 01 .
    When doing this the engine must be running at idle speed
 
→ Indicated on display:
Rapid data transfer    HELP
Select function XX
  • ‒ Switch on the fault reader printer with the print key. The indicator lamp in the key must light up.
  • ‒ Enter "08" to select the function "Reading measured value block" and confirm entry with Q key.
 
→ Indicated on display:
Reading measured value block    Q
Enter display group number XXX
  • ‒ Enter the required display group number =>Display groups, Page 01-56.
  • ‒ Confirm input with the Q key.
 
→ Display for display group 001 (example):
Reading measured value block    1    ⇒
1    2    3    4

Notes:

  • ◆ If the printer is switched on, the current display can be printed out on the record slip.
  • ◆ Proceed as follows to switch to a different display group:

Display group

V.A.G 1551

VAS 5051

Up

Press key 3

Press s key

Lower

Press key 1

Press s key

  • ‒ If all the display zones show the specified values, press the ⇒ key.

Display group overview > < Encoding table