audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Display Group overview with test table > < Coding table
Simos injection and ignition system (4-cylinder)
Self-diagnosis
Read measured value block
  • ‒ Connect fault reader V.A.G 1551 (V.A.G 1552) and select engine electronics control unit with the "Address word" 01. When doing this the engine must be running at idling speed.
    (Connecting fault reader and selecting engine electronics control unit .)
 
→ Indicated on display:
Rapid data transfer    HELP
Select function XX
  • ‒ Press keys 0 and 8 for the function "Read measured value block" and confirm entry with Q key.
 
→ Indicated on display:
Read measured value block
Enter display group number XXX
  • ‒ Enter relevant Display Group number (3 figures) and confirm entry by pressing Q.

Example: To select Display Group 5, press keys 0, 0 and 5.

Note:

To change to another display group proceed as follows:

Display group

V.A.G 1551

V.A.G 1552

Higher

Press key 3

Press ↑key

Lower

Press key 1

Press ↓key

Test conditions

  • ● No faults stored in fault memory
    => Page 01-10, interrogating fault memory
  • ● Vehicle stationary, engine idling, throttle valve closed
  • ● Coolant temperature at least 80 °C
  • ● Electrical consumers switched off
  • ● Air conditioner switched off
  • ● On vehicles with automatic gearboxes, the selector lever must be in either P or N position.

Display Group overview with test table > < Coding table