ESP Fault table
Fault table; fault codes from 01435 to 01542
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
|
|
01435
|
|
|
Brake pressure sender -G201
|
- The brake light switch is either incorrectly adjusted or incorrectly installed.
|
- Check whether the brake light switch is correctly positioned. => Brake System; Repair group 4501-249, display group 5
|
Continued next page.
|
- Open circuit in signal wire of brake pressure sender -G201. - Short to positive/earth in signal wire of brake pressure sender -G21.
|
- Check signal wire of brake pressure sender -G201, contact 2 to control unit -J104, contact 68. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
---|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
|
|
01435
|
|
|
Brake pressure sender -G201
Continued:
|
- Brake pressure sender -G201 defective.
|
- If none of the above is the cause of the problem replace ESP hydraulic pump -V156 with brake pressure sender -G201.
|
Continued next page.
|
- Open circuit in one of the voltage supply wires of the brake pressure sender -G201.
|
- Check the earth supply of brake pressure sender -G201, contact 1, to control unit -J104, contact 67 (control unit 4B0 907 389), and/or contact 69 (control unit 8D0 809 389/A/D/E). Check the voltage supply of brake pressure sender -G201, contact 3, to control unit -J104, contact 69 (control unit 4B0 907 389), and/or contact 67 (control unit 8D0 907 389/A/D/E). => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
---|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
|
|
01435
|
|
|
Continued:
|
|
|
Brake pressure sender -G201 Electrical fault in circuit
|
- Open circuit in signal wire of brake pressure sender -G201. - Short to positive/earth in signal wire of brake pressure sender -G21.
|
- Check signal wire of brake pressure sender -G201, contact 2 to control unit -J104, contact 68. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
Continued next page.
|
- Open circuit in one of the voltage supply wires of the brake pressure sender -G201.
|
- Check the earth supply of brake pressure sender -G201, contact 1, to control unit -J104, contact 67 (control unit 4B0 907 389), and/or contact 69 (control unit 8D0 809 389/A/D/E). Check the voltage supply of brake pressure sender -G201, contact 3, to control unit -J104, contact 69 (control unit 4B0 907 389), and/or contact 67 (control unit 8D0 907 389/A/D/E). => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
|
|
01435
|
|
|
Continued:
|
|
|
Brake pressure sender -G201 - Voltage supply
|
- Short to positive in voltage supply.
- Short to earth in voltage supply.
- Open circuit in one of the voltage supply wires of the brake pressure sender -G201.
|
- Check the earth supply of brake pressure sender -G201, contact 1, to control unit -J104, contact 67 (control unit 4B0 907 389), and/or contact 69 (control unit 8D0 809 389/A/D/E). Check the voltage supply of brake pressure sender -G201, contact 3, to control unit -J104, contact 69 (control unit 4B0 907 389), and/or contact 67 (control unit 8D0 907 389/A/D/E). => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
---|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
|
|
01464
|
If this fault is detected by the self-diagnosis, then no distinction has been made between the voltage supply for brake pressure sender -G201 and the voltage supply for lateral acceleration sender -G200. Both components and the corresponding wiring should be checked.
|
Sender for brake pressure/lateral acceleration Voltage supply
|
- Voltage supply for brake pressure sender -G201 is insufficient.
|
- Check the voltage supply wiring between brake pressure sender -G201, contact 3 and control unit -J104, contact 69 for short to earth and short to positive.
|
Continued next page.
|
- Voltage supply for lateral acceleration sender -G200 is insufficient.
|
- Check the voltage supply wiring between lateral acceleration sender -G200, contact 3 and control unit -J104, contact 75 for short to earth and short to positive.
|
|
---|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
|
|
01464
|
If this fault is detected by the self-diagnosis, then no distinction has been made between the voltage supply for brake pressure sender -G201 and the voltage supply for lateral acceleration sender -G200. Both components and the corresponding wiring should be checked.
|
Sender for brake pressure/lateral acceleration Voltage supply
Continued:
|
- One of the two senders is faulty.
|
If no fault can be found with the voltage supply wiring:
|
|
- Control unit -J104 defective. Note: Replacement of the control unit is always the final option.
|
- If the fault cannot be traced by any of these steps, renew control unit -J104
|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
Note: this fault is not present in fault readers V.A.G 1551/52.
|
01486
|
|
|
System function test activated
|
- ESP system test activated.
|
- Perform the ESP driving and system test in full
|
|
---|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
|
|
01542
|
|
Yaw rate sender -G202 Implausible signal
|
The input signals received by control unit -J104 are processed by internal programs and tested for plausibility. In the case of yaw rate sender -G202, the program mainly relies on the steering angle sender -G85 and the lateral acceleration sender -G200. If the yaw rate sender -G202 is suspected of being the cause of the problem a check must be made to ensure that the steering angle sender -G85 and the lateral acceleration sender -G200 are functioning properly. They must also be checked. With vehicle moving in a straight line (v < 20 km/h) check zero position of steering angle sender -G85 by selecting function 08 "Read measured value block", => Page 01-249, display group 5.
|
Continued next page.
|
This test will give one of four possible results:
|
|
---|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
|
|
01542
|
|
|
Yaw rate sender -G202 Implausible signal
Continued:
|
Test result 1: (also refer to test result 4): Zero position of steering angle sender outside specified tolerance and zero position of yaw rate sender within specified tolerance.
|
Continued next page.
|
|
- Perform zero position compensation. If the fault is still present, perform test steps listed for test result 2.
|
|
---|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
Note: Applies only to control unit no.: 4B0 907.389
|
01542
|
|
|
Yaw rate sender -G202 Implausible signal
Continued:
|
Test result 2: (also refer to test result 4): Zero position of steering angle sender within specified tolerance and zero position of yaw rate sender -G202 outside specified tolerance.
|
Continued next page.
|
- Open circuit in signal wire of yaw rate sender -G202. - Short to positive/earth in signal wire of yaw rate sender -G202.
|
- Check signal wire of yaw rate sender -G202, contact 3 to control unit -J104, contact 79. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
Note: Applies only to control unit no.: 4B0 907.389
|
01542
|
|
|
Yaw rate sender -G202 Implausible signal
Continued: (Test result 2)
Continued next page.
|
- Open circuit in one of the voltage supply wires of the yaw rate sender -G202.
|
- Check earth connection of yaw rate sender -G202, contact 1 to control unit -J104, contact 80. Check voltage supply of yaw rate sender -G202, contact 2 to control unit -J104, contact 34. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
Note: Applies only to control unit nos.: 8D0 907 389, 8D0 907 389A, 8D0 907 389D and 8D0 907 389E.
|
01542
|
|
|
Yaw rate sender -G202 Implausible signal
Continued:
|
Test result 2: (also refer to test result 4): Zero position of steering angle sender is inside specified tolerance and zero position of lateral acceleration sensor -G200 is outside specified tolerance:
|
|
- Open circuit in one of the signal wires for the combined yaw rate and lateral acceleration sender. - Short to positive/earth in one of the signal wires of the combined yaw rate and lateral acceleration sender.
|
- Check signal wire between combined yaw rate and lateral acceleration sender, contact 4 and control unit -J104, contact 18. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
Note: Applies only to control unit nos.: 8D0 907 389, 8D0 907 389A, 8D0 907 389D and 8D0 907 389E.
|
01542
|
|
|
Yaw rate sender -G202 Implausible signal
Continued: (Test result 2)
Continued next page.
|
- Open circuit in one of the voltage supply wires for the combined yaw rate and lateral acceleration sender.
|
- Check earth connection between combined yaw rate and lateral acceleration sender, contact 2 and control unit -J104, contact 80. Check voltage supply between combined yaw rate and lateral acceleration sender, contact 1 and control unit -J104, contact 34. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
---|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
|
|
01542
|
|
|
Yaw rate sender -G202 Implausible signal
Continued:
|
Test result 3: (also refer to test result 4): Zero position of steering angle sender is outside specified tolerance and zero position of lateral acceleration sensor -G200 is outside specified tolerance:
|
|
- Perform test steps 1 and 2.
|
Continued next page.
|
|
|
---|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
Note: Applies only to control unit no.: 4B0 907 389
|
01542
|
|
|
Yaw rate sender -G202 Implausible signal
Continued:
|
Test result 4: Zero position of steering angle sender within specified tolerance and zero position of lateral acceleration sender -G200 inside specified tolerance.
|
|
- Check yaw rate sender -G202 by selecting function 08 "Read measured value block", => Page 01-249, display group 5,
|
|
- Yaw rate sender -G202 is loose.
|
- Check mounting of yaw rate sender -G202.
|
Continued next page.
|
- Open circuit in signal wire of yaw rate sender -G202. - Short to positive/earth in signal wire of yaw rate sender -G202.
|
- Check signal wire of yaw rate sender -G202, contact 3 to control unit -J104, contact 79. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
---|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
Note: Applies only to control unit no.: 4B0 907 389
|
01542
|
|
|
Yaw rate sender -G202 Implausible signal
|
- Open circuit in one of the voltage supply wires of the yaw rate sender -G202.
|
- Check earth connection of yaw rate sender -G202, contact 1 to control unit -J104, contact 80.
|
Continued: (Test result 4)
|
|
- Check voltage supply of yaw rate sender -G202, contact 2 to control unit -J104, contact 34. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
Continued next page.
|
- Open circuit in test wire of yaw rate sender -G202. - Short to positive/earth in test wire of yaw rate sender -G202.
|
- Check test wire of yaw rate sender -G202, contact 5 to control unit -J104, contact 77. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
---|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
Note: Applies only to control unit nos.: 8D0 907 389, 8D0 907 389A, 8D0 907 389D and 8D0 907 389E.
|
01542
|
|
|
Yaw rate sender -G202 Implausible signal
Continued:
|
Test result 4: Zero position of steering angle sender is inside specified tolerance and zero position of combined yaw rate and lateral acceleration sender is inside specified tolerance:
|
|
- Check combined yaw rate and lateral acceleration sender by selecting function 08 "Read measured value block", => Page 01-249, display group 5
|
Continued next page.
|
- Combined yaw rate and lateral acceleration sender is loose.
|
- Check mounting of combined yaw rate and lateral acceleration sender.
|
|
---|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
Note: Applies only to control unit nos.: 8D0 907 389, 8D0 907 389A, 8D0 907 389D and 8D0 907 389E.
|
01542
|
|
|
Yaw rate sender -G202 Implausible signal
Continued: (Test result 4)
Continued next page.
|
- Open circuit in one of the voltage supply wires for the combined yaw rate and lateral acceleration sender.
|
- Check earth connection between combined yaw rate and lateral acceleration sender, contact 2 and control unit -J104, contact 80. Check voltage supply between combined yaw rate and lateral acceleration sender, contact 1 and control unit -J104, contact 34. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
V.A.G 1551 printer
|
Possible causes of fault
|
Fault remedy
|
Fault code
|
Note: Applies only to control unit nos.: 8D0 907 389, 8D0 907 389A, 8D0 907 389D and 8D0 907 389E.
|
01542
|
|
|
Yaw rate sender -G202 Implausible signal
Continued: (Test result 4)
|
- Open circuit in one of the signal wires for the combined yaw rate and lateral acceleration sender. - Short to positive/earth in one of the signal wires of the combined yaw rate and lateral acceleration sender.
|
- Check signal wire between combined yaw rate and lateral acceleration sender, contact 6 and control unit -J104, contact 79. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
Continued next page.
|
- Open circuit in test wire of combined yaw rate and lateral acceleration sender. - Short to positive/earth in test wire of the combined yaw rate and lateral acceleration sender.
|
- Check test wire between combined yaw rate and lateral acceleration sender, contact 3 and control unit -J104, contact 77. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|