audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Adaption > < Encoding control unit
Reading measured value block
Reading measured value block
   
Sequence of operations
–  Start parking system self-diagnosis → Chapter.
Display on -VAS 5051B-:
–  From list -1-, select function “08 - Reading measured value block”.
  A01-0122
Display on -VAS 5051B-:
1 - Enter display group
–  Use keypad -2- to enter the desired “display group number” → Anchor and confirm the entry by touching the Q key.
  A01-0130
Display on -VAS 5051B-:
1 - Display zones 1 ... 4. If a display zone is not assigned, there is no display on this line.
2 - The display group selected is shown here
3 - Touching these keys permits switching to a different display group.
4 - Touching these keys permits switching to a different function (e.g. from “Reading measured value block” to “Basic setting” and vice versa).
–  Terminate function “08 - Reading measured value block” by touching key.
  A01-0176
List of display groups
Display group 001
Display zonesExplanatory notes
1 Rear left parking aid sender -G203- distance
… cm
l  0 … 200 cm
2 Rear centre left parking aid sender -G204- distance
… cm
l  0 … 200 cm
3 Rear centre right parking aid sender -G205- distance
… cm
l  0 … 200 cm
4 Rear right parking aid sender -G206- distance
… cm
l  0 … 200 cm

   
Display group 002
Display zonesExplanatory notes
1… cmShortest distance of the 4 measured values
2… km/hVehicle speed
3 Warning buzzer
l  Acoustic signal on
l  Acoustic signal off
4 Not used

   
Display group 003
Display zonesExplanatory notes
1… VParking aid sender power supply
2 Reverse gear recognition
l  Reverse yes
l  Reverse no
3 Trailer recognition
l  Trailer yes
l  Trailer no
4 Not used

   
Display group 004
Display zonesExplanatory notes
1 Rear left parking aid sender -G203- decay time
… ms
l  max. 4 ms 1)
2 Rear centre left parking aid sender -G204- decay time
… ms
l  max. 4 ms 1)
3 Rear centre right parking aid sender -G205- decay time
… ms
l  max. 4 ms 1)
4 Rear right parking aid sender -G206- decay time
… ms
l  max. 4 ms 1)
l  1) If the decay time with reverse gear engaged is more than 4.00 ms, either the parking aid sender is defective or there is an open circuit in the wiring.

   

Adaption > < Encoding control unit