Input values on dash panel insert replacement > < Adaption channels 01 … 09
Adaption channels 10 … 30
Adaption channels 10 … 30
   
Adaption channel 10 - Remaining mileage prior to “Oil change service”
This function is used to adapt the remaining mileage prior to the next “Oil change service” on replacing the dash panel insert.
Display on -VAS 5051B-:
1 - Enter channel number
–  On the keypad -2-, touch keys 10 for “Adaption channel 10” and confirm the entry by touching the Q key.
  A01-0130
Display on -VAS 5051B-:
1 - Channel 10 reading and testing
4 - Bar set to current adaption value
  Note
t  The value “15” is the factory-set maximum mileage of 15000 km for the “Oil change service”.
t  Entries can only be made in 1000 km steps; the display is also given in units of 1000 km.
t  The value to be entered is decremented to 0 km.
t  Adaption must be performed in kilometres even in countries with speedometer display in miles. This involves converting the adaption value from miles to kilometres.
–  Use the bar to alter the adaption value ⇒ “A - Altering adaption value by way of bar” → Anchor.
Or
–  Alter the adaption value by means of direct entry ⇒ “B - Altering adaption value by means of direct entry” → Anchor.
–  Enter the adaption value.
  A01-0131
Example:Remaining mileage prior to next oil change service “8000 km”
 Keypad entry 8

  Note
The fault message “Function unknown or cannot be implemented at present” appears if an implausible value is entered.
   
Display on -VAS 5051B- following successful adaption. Example:
1 - Channel 10 value 8 stored
–  Terminate function “10 - Adaption” by touching key.
  A01-0134
Adaption channel 11 - Remaining mileage prior to “Inspection service”
This function is used to adapt the remaining mileage prior to the next “Insepction service” on replacing the dash panel insert.
Display on -VAS 5051B-:
1 - Enter channel number
–  On the keypad -2-, touch keys 11 for “Adaption channel 11” and confirm the entry by touching the Q key.
  A01-0130
Display on -VAS 5051B-:
1 - Channel 11 reading and testing
4 - Bar set to current adaption value
  Note
t  The value “30” is the factory-set maximum mileage of 30000 km for the “Inspection service”.
t  Entries can only be made in 1000 km steps; the display is also given in units of 1000 km.
t  The value to be entered is decremented to 0 km.
t  Adaption must be performed in kilometres even in countries with speedometer display in miles. This involves converting the adaption value from miles to kilometres.
–  Use the bar to alter the adaption value ⇒ “A - Altering adaption value by way of bar” → Anchor.
Or
–  Alter the adaption value by means of direct entry ⇒ “B - Altering adaption value by means of direct entry” → Anchor.
–  Enter the adaption value.
  A01-0131
Example:Remaining mileage prior to next inspection service “14000 km”
 Keypad entry 14

  Note
The fault message “Function unknown or cannot be implemented at present” appears if an implausible value is entered.
   
Display on -VAS 5051B- following successful adaption. Example:
1 - Channel 11 value 14 stored
–  Terminate function “10 - Adaption” by touching key.
  A01-0134
Adaption channel 12 - Remaining time prior to “Inspection service”
This function is used to adapt the remaining time prior to the next “Insepction service” on replacing the dash panel insert.
Display on -VAS 5051B-:
1 - Enter channel number
–  On the keypad -2-, touch keys 12 for “Adaption channel 12” and confirm the entry by touching the Q key.
  A01-0130
Display on -VAS 5051B-:
1 - Channel 12 reading and testing
4 - Bar set to current adaption value
  Note
t  The value “37” is the factory-set maximum time interval of 370 days for the “Inspection service”.
t  Entries can only be made in 10 day steps; the display is also given in units of 10 days.
t  The value to be entered is decremented to 0 days.
–  Use the bar to alter the adaption value ⇒ “A - Altering adaption value by way of bar” → Anchor.
Or
–  Alter the adaption value by means of direct entry ⇒ “B - Altering adaption value by means of direct entry” → Anchor.
–  Enter the adaption value.
  A01-0131
Example:Remaining time for inspection service “170 days”
 Keypad entry 17

  Note
The fault message “Function unknown or cannot be implemented at present” appears if an implausible value is entered.
   
Display on -VAS 5051B- following successful adaption. Example:
Example:
1 - Channel 12 value 17 stored
–  Terminate function “10 - Adaption” by touching key.
  A01-0134
Adaption channel 30 - Correction of fuel gauge sender characteristic curve
This function can be used to correct the resistance characteristic curve of the fuel gauge sender if the display in the dash panel insert does not correspond to the actual tank content.
Display on -VAS 5051B-:
1 - Enter channel number
–  On the keypad -2-, touch keys 30 for “Adaption channel 30” and confirm the entry by touching the Q key.
  A01-0130
Display on -VAS 5051B-:
1 - Channel 30 reading and testing
2 - Fuel gauge sender
4 - Bar set to current adaption value
  Note
t  The value “128” is the factory-set mean resistance characteristic curve of the fuel gauge sender.
t  The resistance characteristic curve of the fuel gauge sender can be altered in the range 120 … 136 Ω.
t  On dash panel insert replacement → Chapter.
–  Use the bar to alter the adaption value ⇒ “A - Altering adaption value by way of bar” → Anchor.
Or
–  Alter the adaption value by means of direct entry ⇒ “B - Altering adaption value by means of direct entry” → Anchor.
–  Enter the adaption value.
  A01-0131
Example:Resistance characteristic curve of fuel gauge sender “132Ω”
 Keypad entry 132

  Note
The fault message “Function unknown or cannot be implemented at present” appears if an implausible value is entered.
   
Display on -VAS 5051B- following successful adaption. Example:
1 - Channel 30 value 132 stored
–  Terminate function “10 - Adaption” by touching key.
  A01-0134

Input values on dash panel insert replacement > < Adaption channels 01 … 09