A4 Mk1
Self-diagnosis of navigation system II-D (Navigation System Plus) (from week 48/99)
Function status register
Functional description Production diagnosis is a special mode for checking the wiring and function capability of the navigation system. An automated check of the individual fault locations is carried out and the result permanently stored in the so-called function status register (measured value block 007). Production diagnosis can be disabled/enabled by way of the "Adaption" function (channel number 03) . Production diagnosis is also disabled when a navigation CD is inserted. The "Erase fault memory" function also resets the function status register. Test requirements: