audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Unscrewing drive plate from compressor/screwing on > < Attaching
Checking concentricity of drive plate with overload safeguard/adjusting
Checking concentricity of drive plate with overload safeguard/adjusting
–  Remove compressor → Chapter.
   
–  Clean flange at drive plate -A-.
–  Attach a dial gauge -B- with dial gauge holder -C- (e.g. universal dial gauge holder -VW 387-) to the compressor.
–  Attach probe of dial gauge -D- to flange of drive plate -A- with a pre-tension of approx. 1.0 mm.
–  Give compressor drive unit -E- several turns.
Specification: Eccentricity less than 0.21 mm (dial gauge deflection, difference between lowest and highest measured value max. 0.2 mm)
–  If eccentricity exceeds 0.2 mm, slacken off bolts at drive plate → Chapter and re-adjust drive plate.
  A87-0624

Unscrewing drive plate from compressor/screwing on > < Attaching