Vehicle diagnostic, testing and information system -VAS 5051A-, measurement mode: Multimeter, voltage measurement (20 VDC) l
| Adapter cable -V.A.G 1598/11- connected |
|
Test step | Test box -V.A.G 1598A- socket | Checking of | | Specification | Measures to be taken if reading does not match specification |
1.4 | 13 + earth → Note | Terminal “75” at operating and display unit, Climatronic control unit -J255- | | t
| approx. battery voltage |
| –
| Use current flow diagram to repair power supply to operating and display unit, Climatronic control unit -J255- |
|
1.5 | 34 + earth → Note | t
| Earth connection at operating and display unit, Climatronic control unit -J255- |
| | | –
| Use current flow diagram to locate and eliminate short to positive in earth connection (signal earth) |
|
1.6 | 13 + 34 | t
| Earth connection at operating and display unit, Climatronic control unit -J255- |
| | | –
| Use current flow diagram to locate and eliminate short to earth in earth connection (signal earth) |
|