Display group “005”
Display group “005”
Defroster flap control motor -V107-
   
Display zoneSignificanceExplanatory notes
1Actual feedback value of defroster flap control motor potentiometer -G135- (in defroster flap control motor -V107-)
l  Display value greater than “9” and less than “251”
l  Maximum permissible deviation “3” units from specified feedback value (only in range greater than “70” but less than “190”)
2Specified feedback value for defroster flap control motor potentiometer -G135- (calculated by operating and display unit, Climatronic control unit -J255-)
l  Display range “10 ... 155 ( ...165)”
–  The “Upper stop” is not reached in control mode; the flap is not moved as far as the stop even in defrost mode.
3Value determined during “Basic setting” and stored in the operating and display unit, Climatronic control unit -J255- for the defroster flap control motor potentiometer -G135- with control motor set to “Lower stop” (defroster flap closed)
l  Display value greater than “9” and less than “71”
4Value determined during “Basic setting” and stored in the operating and display unit, Climatronic control unit -J255- for the defroster flap control motor potentiometer -G135- with control motor set to “Upper stop” (defroster flap open)
l  Display value greater than “189” and less than “246”

  Note
t  At present, the defroster flap is not completely opened even in “Defrost mode”. This results in some of the air always being routed to the other vents. The upper specified feedback value displayed is thus “145... 160”.
t  The notes on display group “003” also apply to this display group and should be heeded if necessary → Anchor.
   