Vehicle diagnostic, testing and information system -VAS 5051A-, measurement mode: Multimeter, resistance measurement (0...100 kΩ) |
Test step | Connection to connector “C” → Chapter | Checking of | | Specification | Measures to be taken if reading does not match specification |
5.1 | Contact “9” and contact “7” | Temperature sensor -G18- and corresponding connections to auxiliary heater control unit -J364- | | –
| Governed by temperature of coolant in auxiliary heater, less than 40 kΩ and greater than 0.34 kΩ (kilo-ohms) |
| –
| Use current flow diagram to check and repair connection to temperature sensor -G18- |
|
5.2 | Contact “9” and contact “10” | Temperature sensor -G18- and corresponding connections to auxiliary heater control unit -J364- | | | –
| Use current flow diagram to locate and eliminate short to earth. |
|